ISSN: 1899-0967
Polish Journal of Radiology
Established by prof. Zygmunt Grudziński in 1926 Sun
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2019
vol. 84
 
Share:
Share:
Neuroradiology
abstract:
Original paper

General technical remarks on 1HMRS translational research in 7T

Katarzyna Kochalska
1
,
Artur Łazorczyk
1
,
Anna Pankowska
1
,
Katarzyna Dyndor
1
,
Paulina Kozioł
1
,
Andrzej Stępniewski
2
,
Radoslaw Pietura
1

1.
Departament of Radiography, Medical University in Lublin, Poland
2.
Centrum ECO-TECH COMPLEX Maria Curie-Skłodowska University in Lublin, Poland
© Pol J Radiol 2019; 84: e190-e197
Online publish date: 2019/04/12
View full text Get citation
 
PlumX metrics:
Purpose
The aim of the work was to share the practical experience of preclinical and clinical proton magnetic resonance spectroscopy (1HMRS) studies conducted using a 7-Tesla magnetic field strength scanner, taking into account the specificity of both settings in the context of translational research.

Material and methods
1HMRS volunteer studies conducted using a Discovery 950 GE 7T scanner, were carried out with PRESS sequence, and a VOI measuring 2.0 × 2.0 × 2.0 cm3 placed in the white matter at the parietal occipital lobe. Rodent spectra obtained using a 7T Bruker were measured with PRESS, with a VOI 2.0 × 2.0 × 5.5 mm3 placed over the hippocampus.

Results
1HMRS data from humans and rats show that the brain spectra obtained in the same field are characterised by a similar neurochemical structure and spectral resolution. Spectra obtained from rats demonstrate the following metabolites: NAA, Glu, Gln, Ins, Cho, Cr, PCr, Tau, GABA, Lac, NAAG, and Asp. In turn, spectra from humans allowed estimation of the following metabolites: Ala, NAA, Glu, Gln, Ins, Cho, Cr, PCr, Tau, GABA, Lac, NAAG, and Asp. Signals from Gln, Glu with chemical shift around 2.4 ppm, from Cr, PCr, and GABA at 3 ppm, and signals from Cho and Tau at approximately 3.2 ppm, can be properly separated and estimated both in humans and in rats.

Conclusions
These results are promising in terms of broadening the knowledge of many neurological diseases by inducing them on animal models and then transferring this knowledge to clinical practice. In spite of this, important distinctions in the technical aspects and methodological differences of high-field 1HMRS in both preclinical and clinical conditions should be taken into account.

keywords:

1HMRS (proton magnetic resonance spectroscopy), UHF (ultra-high field), translational research




Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.