ISSN: 1899-0967
Polish Journal of Radiology
Established by prof. Zygmunt Grudziński in 1926 Sun
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2019
vol. 84
 
Share:
Share:
Breast radiology
abstract:
Original paper

The additive role of 1H-magnetic resonance spectroscopic imaging to ensure pathological complete response after neoadjuvant chemotherapy in breast cancer patients

Dalia Bayoumi
1
,
Mona Zaky
1
,
Dina Abdallah Ibrahim
1
,
Ahmed Abdallah
1
,
Khaled M. Abouelkhair
1

1.
Faculty of Medicine, Mansoura University, Egypt
© Pol J Radiol 2019; 84: e570-e580
Online publish date: 2019/12/20
View full text Get citation
 
PlumX metrics:
Purpose
To assess the role of 1H-magnetic resonance spectroscopy (1H-MRS) in the confirmation of pathological complete response after neoadjuvant chemotherapy in breast cancer.

Material and methods
Forty-seven cases (53.72 ± 8.53 years) were evaluated using magnetic resonance imaging (MRI) and 1H-MRS with choline (Cho) signal-to-noise ratio (SNR) measured followed by histopathology and ROC analyses.

Results
Twelve patients had complete response, and 35 patients had residual disease. Mean age was 53.72 ± 8.53 years. The mean tumour size before neoadjuvant chemotherapy (NAC) was 4.21 ± 0.99 cm and after NAC was 0.9 ± 0.44 cm.Positive total choline signal (tCho) was detected in all cases. The mean Cho SNR before NAC was 9.53 ± 1.7 and after NAC was 2.53 ± 1.3. The Cho SNR cut-off point differentiating between pathologic complete response (pCR) and the non pCR was 1.95. Dynamic MRI showed 83.3% sensitivity, 65.7% specificity, 45.5% positive predictive value, 92.0% negative predictive value, and 70.2% diagnostic accuracy. Combined evaluation done by using the dynamic MRI and 1H-MRS showed 91.5% diagnostic accuracy with 75.0% sensitivity, 97.1% specificity, 75% positive predictive value, and 91.9% negative predictive value. ROC curves of Cho SNR showed statistically significant differences between non pCR and pCR with AUC was 0.955, 82.9% sensitivity, 91.7% specificity, 96.7% positive predictive value, 64.7% negative predictive value, and 85.11% diagnostic accuracy.

Conclusions
1H-MRS improves the diagnostic accuracy in the prediction of the pCR after NAC.