ISSN: 1899-0967
Polish Journal of Radiology
Established by prof. Zygmunt Grudziński in 1926 Sun
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2019
vol. 84
 
Share:
Share:
Gastrointestinal and abdominal radiology
abstract:
Original paper

The efficacy of new oral contrast mixture for computed tomography enterography

Şehnaz Evrimler
1
,
Gökhan Ocakoğlu
2
,
Oktay Algin
3

1.
Suleyman Demirel University, Faculty of Medicine, Department of Radiology, Isparta, Turkey
2.
Uludag University, Faculty of Medicine, Department of Biostatistics, Bursa, Turkey
3.
Yildirim Beyazıt University, Faculty of Medicine, Department of Radiology, Ankara, Turkey
© Pol J Radiol 2019; 84: e403-e412
Online publish date: 2019/10/15
View full text Get citation
 
PlumX metrics:
Purpose
To show the reliabilities of the new mixture (composed of water, methylcellulose, lactulose, locust bean gum, and sorbitol) and to compare the luminal distension and radiological confidence scores of this solution with water-lactulose mixture.

Material and methods
Computed tomography enterography (CTE) images in a three-year period were included randomly in our institutional review board-approved and retrospective study. Ninety-one patients drank a lactulose and water mixture (Group 1), and 54 patients drank the new mixture (Group 2). Patients who drank the oral contrast agent were taken to a 64-detector row multiple detector computed tomography machine. Coronal and sagittal reformatted images were also formed. The gastrointestinal tract was divided into 11 segments for scoring. Each segment was graded for distensional and radiological confidence. CTE images were evaluated by two radiologists.

Results
Inter- and intra-reader reliabilities were good or excellent for all gastrointestinal segments in both groups (p < 0.001). The best κ values were obtained in sigmoid colon assessments. Lower agreement values were detected in duodenum and jejunum scores. The new mixture group (Group 2) showed better results than Group 1 for ileum and colonic segments according to distension and confidence scorings.

Conclusions
Inter- and intra-reader reliabilities of the new mixture were good or excellent for CTE. The new mixture seems to be more efficient and reliable for ileum and colon. The new mixture can increase bowel distention, radiological confidence, and quality in CTE evaluations.

keywords:

reliability, small intestine, CT enterography, oral/rectal contrast