
Current issue
Archive
Manuscripts accepted
About the journal
Editorial board
Abstracting and indexing
Contact
Instructions for authors
Ethical standards and procedures
Editorial System
Submit your Manuscript
|
1/2022
vol. 87 Cardiovascular radiology
abstract:
Original paper
The reaction of arteries to haemodialysis – can a change in the cross-sectional area be an important parameter in the assessment of the vessels’ condition?
Sergiusz Ustyniak
1
,
Ludomir Stefańczyk
1
,
Ilona Kurnatowska
2
,
Magdalena Kaczmarska
1
,
Maciej Goździk
2
1.
Department of Radiology and Diagnostic Imaging, Medical University of Łódź, Poland
2.
Department of Internal Medicine and Transplantation Nephrology, 1st Chair of Internal Medicine, Medical University of Łódź, Poland
Pol J Radiol 2022; 87: e226-e231
Online publish date: 2022/04/15
View full text
Get citation
ENW EndNote
BIB JabRef, Mendeley
RIS Papers, Reference Manager, RefWorks, Zotero
AMA
APA
Chicago
Harvard
MLA
Vancouver
Purpose
The objectives of our study were to evaluate the changes in the cross-section area of carotid and femoral arteries caused by fluid loss during haemodialysis (HD) and to determine the direction and amount of these changes. Material and methods Seventy-four HD patients (28 women and 46 men) were studied. We performed ultrasound exams of the distal common carotid and proximal femoral arteries in each patient before and after a HD session. Recorded exams were analysed using EchoPac software. Arterial cross-section area values were acquired for further analysis. Results We found a statistically significant decrease in arterial systolic cross-section area values after HD sessions (carotid arteries area before HD equalled 0.6731 cm2 and 0.6333 cm2, p = 0.00001 after HD, femoral arteries area before HD equalled 0.8263 cm2 and 0.7635 cm2, p = 0.00001 after HD). The decrease of systolic carotid cross-section area correlated with the amount of fluid lost during HD sessions (correlation coefficient of 0.3122, p = 0.010) and the percentage of the body mass lost during HD (correlation coefficient of 0.3577, p = 0.003). No statistically significant changes were found in the femoral cross-section area. Conclusions Our findings suggest that the arterial cross-section area may be used in the assessment of response to body fluid loss. We were able to measure changes due to fluid loss during the HD session. The carotid cross-section values decreased after the procedure and correlated with the amount of fluid lost during the HD session. keywords:
haemodynamics, ultrasonography, renal dialysis, vascular stiffness, carotid arteries, femoral artery |